Induction hob with integrated vapour extraction GOLD
KMDA 7473-1 FL Silence
800 mm | Extraction and recirculation | SilenceMotor | Flex cooking areasale priceINR459,990.00
Product details
- The quietest TwoInOne from Miele –Silence motorLoading...
- Ample space – 4 large cooking zones incl.2 Flex zonesLoading...
- Automatic fan power regulation –Con@ctivityLoading...
- Compact control using the numerical display –ComfortSelect PlusLoading...
- Flexible installation – Plug & Play, ducted recirculation or vented system
- View manufacturer details:
- Safety Information
Model identifier KMDA 7473-1 FL Silence
Manufacturer material number 12968760
EAN number 4002516974680
Marketing class Gold
Loading...
Heating type Induction
Induction hob with integrated vapour extraction
Exhaust air guided with optional accessories DFK-xxxx,DMK 150-1
Recirculation air guided with optional accessories DFK-xxxx,DUU 1500,DUU 600
Unguided recirculation air (Plug&Play installation)
Elegant glass ceramic surface
Frameless – surface-mounted
Flush
Ceramic surface colour Black
Flush fit extractor
Colour of cover grille Stainless steel
Number of cooking zones 4
Number of cooking areas 2
Maximum number of pans 4
No. 4
Type Flex cooking zone
Diameter in mm Ø 110-210
Rating in W 2100
Booster in W 3000
Position Left
Type Flex cooking area
Size in mm 210x420
Max. rating in W 3000
Max. Booster power rating in W 3700
Position right
Type Flex cooking zone
Size in mm 210x420
Max. rating in W 3000
Max. Booster power rating in W 3700
Operation via sensor controls ComfortSelect Plus
Loading...
Display colour Yellow
Miele@home
Con@ctivity
Loading...
Digital power level display
Permanent pan recognition
Loading...
Keeping warm
Stop & Go function
Recall function
Loading...
Minute minder
Safety switch-off
Auto heat-up
Individual setting options (e.g. buzzers)
Loading...
Run-on time 5/15 min.
Active charcoal filter saturation indicator
Energy efficiency class (A+++ to D) A+
Annual energy consumption in kWh/year 31.3
Fluid dynamic efficiency class A
Lighting efficiency class NA
Grease filtering efficiency class A
ECO motor
Loading...
Silence motor
Loading...
Easy to clean ceramic glass
Wipe protection
Easy-to-clean canopy interior – CleanCover
Loading...
Quick cleaning of cooker hood interior
Intensive cleaning of cooker hood interior
Number of dishwasher-safe metal grease filters (10-ply) 1
Air throughput at min. level (m³/h) according to EN 61591 205
Air throughput at max. level (m³/h) according to EN 61591 533
Air throughput in Intensive level (m³/h) according to EN 61591 606
Sound power at min. level (dB(A) re 1 pW) according to EN 60704-3 41
Sound power at max. level (dB(A) re 1 pW) according to EN 60704-3 64
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 68
Sound pressure at min. level (dB(A) re 20 µPa) according to EN 60704-2-13 28
Sound pressure at max. level (dB(A) re 20 µPa) according to EN 60704-2-13 51
Noise pressure level in Intensive level (dB(A) re 20 µPa) according to EN 60704-2-13 54
Air throughput at min. level (m³/h) according to EN 61591 160
Air throughput at max. level (m³/h) according to EN 61591 475
Air throughput in Intensive level (m³/h) according to EN 61591 510
Sound power at min. level (dB(A) re 1 pW) according to EN 60704-3 46
Sound power at max. level (dB(A) re 1 pW) according to EN 60704-3 68
Noise power level in Intensive level (dB(A) re 1 pW) according to EN 60704-3 70
Sound pressure at min. level (dB(A) re 20 µPa) according to EN 60704-2-13 33
Sound pressure at max. level (dB(A) re 20 µPa) according to EN 60704-2-13 55
Noise pressure level in Intensive level (dB(A) re 20 µPa) according to EN 60704-2-13 57
Safety switch-off
Loading...
Lock function
Loading...
System lock
Integrated cooling fan
Overheating protection
Residual heat indicator
Connection for window contact switch
Dimensions (W x H x D) in mm 800 x 200 x 520
Dimensions in mm (width) 800
Dimensions in mm (height) 200
Dimensions in mm (depth) 520
Casing height incl. connection box in mm 200
Cutout dimensions in mm (width) with surface-mounted installation 780 mm
Cutout dimensions in mm (depth) with surface-mounted installation 500 mm
Internal cutout dimensions in mm (width) with flush installation 780
Internal cutout dimensions in mm (depth) with flush installation 500
External cutout dimensions in mm (width) with flush installation 804
External cutout dimensions in mm (depth) with flush installation 524
Weight in kg 15
Total rated load in kW 7.500
Voltage in V 230
Frequency in Hz 50-60
Length of supply lead in m 1.6
Mains cable Yes
Active charcoal filter DKF 35-P
Plug&Play adapter
EAN 4002516974680
Mains cable
Active charcoal filter DKF 35-P
Plug&Play adapter

Miele CleanCover
Protection and easy cleaning: the smooth concealed surface prevents contact with electrical components and motor.
Stainless steel grease filters
Convenient cleaning: The high-quality metal grease filters are dishwasher-proof and extremely durable.
Flush-fit extractor
Flush and elegant: thanks to the discreet design, you can enjoy maximum design freedom in your kitchen.
Convenient additional functions
Numerous additional functions such as Stop & Go and the timer make life easier in the kitchen.
Silence motor
Extra-quiet: developed by Miele, this motor is 25 % quieter than its predecessor at higher air throughput levels.
FlexZone
Unique space provision: the Miele FlexZones allow you to position large pots and pans behind each other.
Safety functions
Our safety functions prevent any unwanted surprises.
ECO motor
Powerful and quiet: the DC motor is efficient and particularly smooth running.
Permanent pot recognition
Autom. activation of numerical keybank: When turned on, crockery that has been placed is recognised immediately.
Domestic appliance networking with Miele@home1,
Make your life smart: thanks to Miele@home, you can cleverly network your domestic appliances – for more options.
Con@ctivity
Innovative convenience: the cooker hood reacts automatically to settings on the hob.
ComfortSelect Plus
Compact and convenient: all cooking zones and the fan can be operated using a clear central numerical display.Matching products and accessories
Downloads
Whether you are looking to replace an appliance or plan a new kitchen – you will find all the relevant installation drawings for your Miele appliance here. Please note that our products should only be installed and maintained by authorised experts. In the event of queries, please ring us for some no-obligation advice!

Descriptions
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm POSTSCRIPT

Descriptions
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm POSTSCRIPT

Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FL MattFinish/FR, KMDA7272FL/FR, KMDA7473FL/FR, Exhaust air
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7272FL/FR, KMDA7473FL/FR, Exhaust air POSTSCRIPT

Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FL MattFinish/FR, KMDA7272FL/FR, KMDA7473FL/FR, Air circulation
KMDA7272-1FL/FR, KMDA7473-1FL/FL MattFinish/FR, KMDA7272FL/FR, KMDA7473FL/FR, Air circulation POSTSCRIPT

Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FL MattFinish/FR, KMDA7272FL/FR, KMDA7473FL/FR, Plug&Play
KMDA7272-1FL/FR, KMDA7473-1FL/FL MattFinish/FR, KMDA7272FL/FR, KMDA7473FL/FR, Plug&Play POSTSCRIPT

Descriptions
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter POSTSCRIPT

Descriptions
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter POSTSCRIPT

Descriptions
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed. If the carcase rear wall is <gt/> 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter, , x Dimension by which the worktop depth is greater than 600 mm.
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed. If the carcase rear wall is <gt/> 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter, , x Dimension by which the worktop depth is greater than 600 mm. POSTSCRIPT

Descriptions
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed. If the carcase rear wall is <gt/> 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter, , x Dimension by which the worktop depth is greater than 600 mm.
①When routing the exhaust air between the cabinet wall and an adjacent room wall or an adjacent piece of furniture, a minimum distance of 25 mm must be observed. If the carcase rear wall is <gt/> 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., ④Distance from the front of the lower box to the end of the plug & play adapter, , x Dimension by which the worktop depth is greater than 600 mm. POSTSCRIPT

Descriptions
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm. POSTSCRIPT

Descriptions
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation. POSTSCRIPT

Descriptions
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation. POSTSCRIPT

Descriptions
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ② The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ② The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm. POSTSCRIPT


Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90 POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90 POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm. POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm. POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm. POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm. POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm. POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BH 90, 4) DFK-A, 5) DMK 150-1
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BH 90, 4) DFK-A, 5) DMK 150-1 POSTSCRIPT

Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DMK 150-1
1) DFK-AK 90, 2) DFK-R 1000, 3) DMK 150-1 POSTSCRIPT


Descriptions
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BH 90, 4) DFK-A, 5) DMK 150-1
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BH 90, 4) DFK-A, 5) DMK 150-1 POSTSCRIPT


Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish, KMDA7272FL/FR, KMDA7473FL/FR, Exhaust air
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7272FL/FR, KMDA7473FL/FR, Exhaust air POSTSCRIPT

Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish, KMDA7272FL/FR, KMDA7473FL/FR, Air circulation
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7272FL/FR, KMDA7473FL/FR, Air circulation POSTSCRIPT

Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish - surface installation, 21 cm, drilling template
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish - surface installation, 21 cm, drilling template POSTSCRIPT

Descriptions
KMDA7272-1FL, KMDA7473-1FL, KMDA7473-1FL MattFinish - flush installation, drilling template, Installation depth 21 cm
KMDA7272-1FL, KMDA7473-1FL, KMDA7473-1FL MattFinish - flush installation, drilling template, Installation depth 21 cm POSTSCRIPT

Descriptions
KMDA7272-1FL, KMDA7473-1FL, KMDA7473-1FL MattFinish - flush installation, drilling template, Installation depth 20 cm
KMDA7272-1FL, KMDA7473-1FL, KMDA7473-1FL MattFinish - flush installation, drilling template, Installation depth 20 cm POSTSCRIPT

Descriptions
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish - surface installation, drilling template
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish - surface installation, drilling template POSTSCRIPT

Descriptions
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
KMDA7473-1FL, KMDA7473-1FL MattFinish - Side view flush+X POSTSCRIPT

Descriptions
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
KMDA7473-1FL, KMDA7473-1FL MattFinish - Side view lying on top+X POSTSCRIPT

Descriptions
1) DMK 150-1, 2) DRK-R 1000, 3) DRK-V
KMDA7473-1FL, KMDA7473-1FL MattFinish - Installation variant 15 Exhaust air POSTSCRIPT

Descriptions
✓Required, • Not required
KMDA7272-1FL/FR, KMDA7473-1FL/FR, KMDA7473-1FL MattFinish, KMDA7676-1FL, KMDA7876-1FL - Operating options POSTSCRIPT
- 1.This is a separate digital offer from Miele & Cie. KG. The range of functions can vary depending on the model and the country. Acceptance of the Terms and Conditions and Privacy Policy for Miele digital products and services in the Miele app required. Miele reserves the right to change or discontinue the digital offer at any time.
We reserve the right to make technical changes; we assume no liability for the accuracy of the information provided.





